Add to Cart
Industrial Chiller Specification:
Model Item | BZY-05A | |
Nominal cooling capacity | Kcal/h | 12885 |
kw | 15 | |
Power supply | 3PH~380V/50HZ 三相~380V/50HZ | |
Refrigerant | Type | R22/R407C/R134A/R410A/R404A |
Type of control | Expansion valve | |
Compressor | Type | Hermetic scroll type |
Power (HP) | 5 | |
Condenser | Type | Finned copper tube+low noise outer rotor fan |
Power(kw) | 0.18*2 | |
Cooling air flow(m3 /h) | 8470 | |
Evaporator | Type | Water tank type |
Chilled water flow(m3 /h) | 6 | |
Water Tank Capacity | 70 | |
Inlet/outlet pipe chiller(inch) | 1 | |
Water pump | Power(kw) | 0.375 |
Lift(m) | 19 | |
Safety protection | compressor over temperature, over-current protection, high and low pressure protection, over -temperature protection ,flow switch protection,phase sequence or missing phase protection,exhaust overheating protection | |
Net weight | KG | 170 |
Machine size(mm) | mm | 1310*630*1230 |
Features:
High efficiency and energy saving, the COP can reach 4.0.
Compact size, small occupied area.
304 stainless steel evaporator, longer service life
15kw of cooling capacity, customization available.
Product Highlights:
Brand compressor, energy saving 20-30%, stable operation, high efficiency, External corrugated hydrophilic aluminum foil to increase heat dissipation area,
low failure rate, long service life, etc. internal all-copper high-efficiency condenser
304 stainless steel insulated water tank; Anti-icing protection device. LCD display, easy operation, multi-language support, safety tips
External axial flow fan, effectively saving 30% of energy Lightweight, stable throttling, light corrosion resistance
The air-cooled chiller uses a 304 stainless steel water tank evaporator. In the refrigeration system, the refrigerant evaporates in the heat exchange tube and the water flows on the side of the water tank, which improves the heat exchange efficiency. In addition, in order to maintain a stable working temperature, the evaporator shell is covered with insulation material and the heat exchange tube uses a high-efficiency seamless copper tube. The inner groove of the tube forms an internal threaded fin to increase the heat exchange area with the refrigerant. Through this technology, the heat transfer area is doubled, greatly improving the heat transfer efficiency.
How to select the model of the chiller ?
1. We need to know the heat load of your process or chiller cooling capacity, it can be calculated roughly according to production capacity.
2. Required water temperature, water pressure and flow rate.
3. Application and power supply in local.
4. Max. Ambient temperature in summer day.
5. Customized special specifications are acceptable. Contact us for more chiller Specification by number +86 18681056691